Description
Functions
IOT Solution
Compatible with Dahua DSS Pro platform and Wisualarm Business platform, to realize CCTV&Fire Alarm linkage and the one-stop management.
Power Supply Management
Smart power supply management offers main power supply and backup power supply monitoring, automatically switch power supply, power supply fault reporting, and backup power supply protection.
Editable Alarm Linkage
The linkage strategy is flexible, meeting the fire linkage requirements of complex buildings. It can be edit by the Panel directly or by the configuration software.
Comprehensive Interface Options
1*USB port, 1*network port, 1*fault interface (28VDC); 7*fire alarm interface (28VDC); 7*I/O module interface; 1*DC28V 2A; 2*RS485; 1*RS232; 2*CAN.
Technical Specification
| Parameter | Specification |
|---|---|
| Main Power Supply | AC90-240V/50Hz, 60Hz |
| Backup Power | 2 lead-acid batteries (12V/5Ah each) |
| Log Record | Max. 2048 |
| Display Mode | 480 × 272 4.3″ LCD screen |
| Working Voltage | DC 12V~48V |
| Communication Mode | Two bus line |
| Platform Access | 4G, Ethernet |
| Networking Mode | RS485 |
| Communication Interface | USB, RJ45, CAN, RS232, RS485, One fire alarm output and one fault output |
| Load Capacity | Loop Number: 1 or 2 Zone Number: 0, 8 or 16 Device Linkage Terminals: 7 groups |
| Storage Capacity | 9,999 historical records |
| Communication Distance | 1500 m |
| Shell Material | Chassis: Cold-rolled steel plate SPCC |
| Dimensions | 550 mm × 460 mm × 1707 mm |
| Operating Temperature | -10°C to +55°C |
| Storage Temperature | -20°C to +65°C |
| Operating Humidity | ≤ 95% RH (no condensation) |
| Compliance Standard | EN54-2, EN54-4 |
System Specification
| Parameter | Specification |
|---|---|
| Loop Number | 1 loop for DHI-HY-1022(R) 2 loops for DHI-HY-1025(R) |
| Topology Mode | Class A for DHI-HY-1022R and DHI-HY-1025R Class B for DHI-HY-1022 and DHI-HY-1025 |
| Loop Capability | Max. 254 sensors and modules for each loop |
| Optional Built-in Micro Thermal Printer | Option 1: With printer by default Option 2: Without printer by default |
| Simulated Zone | Every 32 addresses form a zone Applicable only to panels with a printer |
| Panel Cascading | Max. 128 panels to cascade |
| Solution Verification | With the help of Dahua Fire (Wisualarm) Presale Tool Performance Limitations Communication Distance Required Battery Specifications |
| Configurable Alarm Linkage | With the help of ControlConfig Tool |
| IOT Solution | Online Solution: Wisualarm Cloud Platform Local Solution: DSS Pro Platform V8.5-V8.7 (Server is required) |
| Compatible Cable Specifications | 2X1.5mm² / 2X16AWG |
| Communication Distance | 1500m (standard) – 3000m (extendable) |
| Telephone&Broadcast System | Optional peripheral system |