TX7110-Intelligent Dual Heat Detector TX7110-smoke-detector-LPCB

Intelligent Dual Heat Detector

The TX7110 Intelligent Fixed and Rate of Rise Heat Detector is reliable for application in places where may have high dust level or smoky environments, making a normal smoke detector undesirable.

The unit manufactured base on the sensitivity requirement of EN 54 part 5, European Standard.

SKU:

TX7110

Certification:

LPCB

Brand:

Description

overview

The unit is aesthetically pleasing with unobtrusive design that will complement modern building designs. The unit incorporates an intelligent processor that provides inbuilt A/D converter, and Self-Diagnosis and History log.

In the event of fire, the integral microprocessor analyses the signal according to factors such as signal strength and rate of increase, then confirms these patterns with the pre-programmed fire scenarios, heat patterns including rate of rise temperature patterns, for a faster and safer response. Once it is confirmed, the LED indicates the sensor status and parallel sending communication signal to the control panel.

The TX7110 detector is compatible to the TX7004 Analogue Intelligent Fire Alarm Control Panel, produced by single manufacture T&A, to avoid addressable communication compatibility problem.

Features and Benefits

• EN 54-5:2000 + A1:2002 Compliance.
• LPCB Approved.
• Using microprocessor technology with memory capacity up to 10 events.
• Analogue sensor and digital addressing.
• Provide real time algorithm to the control panel.
• 360-degree visual indicator.
• Onsite Adjustable Parameter.
• Ancillary remote indicator output.
• Aesthetically pleasing design.

Additional information

Cerfication

LPCB

Listed LPCB / CE-CPR
Certified EN 54-5:2000 + A1:2002
Power Rating  
Input Voltage 24VDC [16V to 28V]
Current Consumption Standby 0.6mA, Alarm: 4mA
Detector  
Protocol / Addressing T&A, Value range from 1 to 254
Heat Class Type A1R
Indicator Single LED / 360-degree Visual
Material / Color ABS / White Glossy finishing
Dimension / Height Diameter 99.7 mm / 57 mm
Weight 127g (with Base), 72g (without Base)
Operating Temperature -10℃~+50℃
Humidity 0 to 95% Relative Humidity, Non condensing

Terminal Description

  1. Signal In (+)
  2. Signal Out (+)
  3. Remote Indicator (+)
  4. Remote Indicator (+)
  5. Signal In (-)
  6. Signal Out (-)
  7. Remote Indicator (-)