TX7120-Intelligent-Addressable-Smoke-Heat-Detector TX7120-LPCB-Certification

Intelligent Addressable Smoke & Heat Detector

The TX7120 Intelligent Addressable Optical Smoke & Heat Detector is the ideal device for most applications, due to its spiffing linear response to a wide variety of different types of smoke patterns and combining with heat sensing sensor for temperature response.

The unit manufactured base on the sensitivity requirement of EN 54 part 29, European Standard.

SKU:

TX7120

Certification:

LPCB

Brand:

Description

Intelligent Addressable Smoke & Heat Detector Overview

The TX7120 is aesthetically pleasing with unobtrusive design that will complement modern building designs. The unit incorporates an intelligent processor that provides Algorithm map, inbuilt A/D converter, Drift compensation, and Self-Diagnosis and History log.

Secure and speedy communication through the on-board processor enables the detector to make its own decision, resulting in greater automation. In the event of fire, the integral microprocessor analyses the signal according to factors such as signal strength and rate of increase, then confirms these patterns with the pre-programmed fire scenarios, smoke and heat patterns including rate of rise temperature, for a faster and safer response.

Once it is confirmed, the LED indicates the sensor status and parallel sending communication signal to the control panel. The TX7120 detector is compatible to the TX7004 Analogue Intelligent Fire Alarm Control Panel, produced by single manufacture T&A, to avoid addressable communication compatibility problem.

Features and Benefits

• EN54-29 Compliance
• Smoke and Heat Sensor
• Using microprocessor technology with memory capacity up to 10 events
• Analogue sending and digital addressing
• Provide real time algorithm to the control panel
• Smart linear drift compensation
• 360-degree visual indicator
• Onsite Adjustable Parameter
• Removable chamber against dust and small insect
• Ancillary remote indicator output
• Aesthetically pleasing design

Additional information

Cerfication

LPCB

Listed LPCB Pending
Certified EN54-29
Power Rating
Input Voltage 24VDC [16V to 28V]
Detector Standby 0.6mA, Alarm: 4mA
Current Consumption Standby 0.6mA, Alarm: 4mA
Protocol / Addressing T&A, Value range from 1 to 254
Smoke Sensitivity As per stipulated standard
Heat Class Type A2R
Indicator Single LED / 360-degree Visual
Material / Color ABS / White Glossy finishing
Dimension / Height Diameter 99.7 mm / 57 mm
Weight 145g (with Base), 90g (without Base)
Operating Temperature -10℃~+50℃
Humidity 0 to 95% Relative Humidity, Non condensing

Terminal Description

  1. Signal In (+)
  2. Signal Out (+)
  3. Remote Indicator (+)
  4. Remote Indicator (+)
  5. Signal In (-)
  6. Signal Out (-)
  7. Remote Indicator (-)
  8. Remote Indicator (-)
 

TX7100-smoke-detector-wiring

TX7120-smoke-detector-size

TX7100-smoke-detector-size

Related Products