TX7100-smoke-detector TX7100-smoke-detector-LPCB TX7100-Addressable-Smoke-Detector-01 TX7100-Addressable-Smoke-Detector-02 TX7100-Addressable-Smoke-Detector-TX7980-Base TX7100-Addressable-Smoke-Detector-TX7980-Base-02

LPCB Ceiling Mount Smoke Detector

The TX7100 Intelligent Addressable Optical Smoke Detector is the ideal device for most applications, due to its spiffing linear response to a wide variety of different types of smoke patterns.

The unit manufactured the sensitivity requirement of EN 54 part 7, European Standard. The unit is aesthetically pleasing with unobtrusive design that will complement modern building designs.

The unit is aesthetically pleasing with unobtrusive design that will complement modern building designs.

SKU:

TX7100

Certification:

LPCB, CE, CPR, EN54

Brand:

Description

Overview – LPCB Ceiling Mount Smoke Detector

The unit incorporates an intelligent processor that provides Algorithm map, inbuilt A/D converter, Drift compensation, and Self-Diagnosis and History log.

Secure and speedy communication through the on-board processor enables the detector to make its own decision, resulting in greater automation. In the event of fire, the integral microprocessor analyses the signal according to factors such as signal strength and rate of increase, then confirms these patterns with the pre-programmed fire scenarios and smoke patterns, for a faster and safer response. Once it is confirmed, the LED indicates the sensor status and parallel sending communication signal to the control
panel.

The TX7100 detector is compatible to the TX7004 Analogue Intelligent Fire Alarm Control Panel, produced by single manufacture Tanda, to avoid addressable communication compatibility problem

Features and Benefits

• EN54-7:2000 +A1:2002 +A2:2006 Compliance.
• LPCB Approved.
• Using microprocessor technology with memory capacity up to 10 events.
• Analogue sending and digital addressing.
• Provide real time algorithm to the control panel.
• Smart linear drift compensation.
• Onsite adjustable parameter.
• 360-degree visual indicator.
• Removable chamber against dust and small insect.
• Ancillary remote indicator output Aesthetically pleasing design.

Additional information

Certification

LPCB, CE, CPR, EN54

TX7100 Intelligent Smoke Detector Coverage

The coverage range of TX7100 smoke detectors presents two gradients, mainly depending on the installation height:

When the installation height is not higher than 6 meters, the coverage radius is 5.8 meters, and the area is about 60 square meters;

when the height is between 6 meters and 12 meters, the coverage radius is 6.7 meters, and the area is about 80 square meters.

When the height of the building is higher than 8 meters, it is recommended to choose TX7130 infrared beam smoke detector, which is summarized in the following table:

TX7100 smoke-detector-cover-range

1. How to test smoke detector?

Detector Configuration, includ detector addressing, set LED On/Off and read configuration, you can program the detector with the TX7932 programmer.

2. Do smoke detectors detect carbon monoxide?

No, this TX7100 can not detect somke and carbon monoxide at the same time, but the model TX7120 smoke and gas detector can do these.

3. Where to install smoke detectors?

Due to the coverage space, it is recommended that TX7100 is installed under 8 meters high, while the TX7130 beam smoke detector is installed above 8 meters high.

Terminal Description

  1. Signal In (+)
  2. Signal Out (+)
  3. Remote Indicator (+)
  4. Remote Indicator (+)
  5. Signal In (-)
  6. Signal Out (-)
  7. Remote Indicator (-)
  8. Remote Indicator (-)
 

TX7100-smoke-detector-wiring

 

TX7100-smoke-detector-size

TX7100-smoke-detector-size