Max 8 Loops 3-in-1 Fire AlarmPanel: FACP, FTS & FBS

The TX7008R comprise of a range of analogue addressable, microprocessor-based fire alarm control equipment to offer flexibility in both design and operation. The System is modular concept for easy tailoring of system design, to meet the full requirements of the project.

The TX7008 Intelligent Fire Alarm Control Panel is designed and manufactured to meet the requirement of BS EN54 Part 2&4.

The TX7008R 3-in-1 Fire Alarm Panel: FACP, FTS & FBS is fitted in a rack enclosure and has more space to install other system including optional TANDA TG7 voice alarm system and TANDA TN7 fire telephone system in a single rack cabinet.

SKU:

TX7008R

Certification:

Brand:

Description

Features and Benefits

• Compliance EN54-2 and EN54-4.
• Using advance microprocessor technology with Large memory capacity.
• Built-in USB port for commissioning purpose.
• Enhance user interface combining LCD Touch screen and keypad access.
• Support real time visual algorithm.
• Enhance false alarm prevention.
• Keypad and PC programming .
• Optional Multiple interface protocol such as USB/Ethernet/CanBus/ Serial/RS485.
• Support Loop Powered devices for extra saving on cable cost.
• Built-In Printer and 160 LED Zones Indicators . Commissioning Advantage
• Auto Enrolling of Devices.
• Loop Mapping with colour coding status.
• Monitor device mismatch and dual address conflict.
• Command Builder to create requirements for fire event scenario.
• With Loop protection against power surge.
• One-man test with On/Off sounder Programming Protection.

System Capacity

• Maximum 8 loop in network application
• Support 254 Devices (2,032 ideal)
• Network up to 512 Node
• Programmable Capacity
• Zones up to 3000
• Sounders Groups 1-1000
• Modules Groups 1001- 2000
• Built-in 160 LED Zones Indicator

Commissioning Advantage

• Auto Enrolling of Devices.
• Loop Mapping with colour coding status.
• Monitor device mismatch and dual address conflict.
• Command Builder to create requirements for fire event scenario.
• With Loop protection against power surge.
• One-man test with On/Off sounder Programming Protection.

Input Voltage 230VAC +10%-15%,50Hz Humidity 0 to 95% Relative Humidity, Non condensing
Network Panel to panel 512 Panels- Single Ring[Ideal] Temperature -5℃~+40℃
Communication Card CanBus Dimension/HWD 1715 x 550 x 480mm
Protocol/Addressing T&A, Value range from 1 to 254 Material/Color Flat sheet Metal /Black
No. of Loop 10 Loop Standalone Keypad 5 Brigade buttons and Programming Keypad
Protection Built-in 4kV Surge protection Display 7”TFT Touch Screen
Programmable Relays 4 circuits: Normally Open/Close Indicator 24 LED Status/ 160 Zone Indicators
Programmable Input 1 Circuit: Power limited 24VDC Fixed Outputs 2 Circuits:Power limited 18-28VDC
Programmable Aux Power Limited 19-28VDC    